Sadler Vertical Reciprocating Conveyors
|
|||
|---|---|---|---|
Item |
Specifications: Imperial and (Metric) |
||
Model Number: |
VR-L4 | VR-L6 | VR-L8 |
| Drive: Brake gearmotor Top mounted |
1 HP (.75 Kw) | 1 HP (.75 Kw) | 2 HP (1.5 Kw) |
| Vertical Lift Bed Speed: Standard |
60 FPM |
60 FPM (20 MPM) |
60 FPM (20 MPM) |
| Vertical Roller Chain: ASA No. | 40-1-R | 60-1-R | 80-1-R |
| Lift Bed Capacity: max weight | 50 lbs (25kg) | 250 lbs (115kg) | 500 lbs (225kg) |
| Load: Max length x width x height |
18" x 13" x 13" (460x330x330mm) |
30" x 24" x 24" (750x600x600mm) |
30" x 24" x 24" (750x600x600mm) |
| Rate in CPM: @ standard speed for: 6' (1.8M) net rise or lift 10' (3.0M) net rise or lift 14' (4.2M) net rise or lift Rate varies directly with speed |
3.2 2.2 1.6 |
3.1 2.1 1.6 |
3.1 2.1 1.6 |
| Footprint of Safety Enclosure: | 4' x 4' (1.2M sq) |
||
| Net Rise or Lift: | 8Ft (2.4M) Standard. |
||
| Height Overall: | 3 Ft above "top of belt" of lift bed conveyor. |
||
| Bottom Feed Height: | 24" (600mm) min top of rollers. |
||
| Feed Conveyors: | Feed conveyors must be capable of presenting or receiving 1 load at a time to synchronize with lift bed conveyor. | ||
| Safety Tunnels: | 2'-6" (1.2M) long for feed conveyors. |
||
| Structure & Safety Enclosure: | Twin cantilevered tubular masts for strength, ease of viewing and preventative maintenance. Not sheet steel with cut-outs and patch doors. Wire mesh 2" x 2" (50 x 50mm) safety enclosure. Free standing full height or in 8'-0" (2.4M) modules. | ||
| Finish: | Sadler medium blue industrial machinery enamel on steam cleaned phosphated steel. | ||
| Controls: | Control panel pre-engineered for standard up or down travel in "auto" mode with safety interlocks for lift bed and feed conveyors. Reversing controls and additional field devices available as optional extra. | ||
| Installation and Assembly: | Each vertical conveyor is pre-wired, pre-tested with feed conveyors and shipped completely assembled by dedicated truck or container. When not completely assembled at the factory (due to height), modules fit together quickly and easily. Work can be done by your crew under our supervision or entirely by Sadler's installation specialists. | ||